Opened 7 years ago

Closed 6 years ago

#3041 closed defect (fixed)

Kea fails to start after repeated start/stop

Reported by: jwright Owned by:
Priority: medium Milestone: Sprint-20131015
Component: ~cmd-ctl (obsolete) Version:
Keywords: Cc:
CVSS Scoring: Parent Tickets:
Sensitive: no Defect Severity: N/A
Sub-Project: Core Feature Depending on Ticket:
Estimated Difficulty: 0 Add Hours to Ticket: 0
Total Hours: 0 Internal?: no

Description

Kea appears to have failed to start after repeated starts/stops. Leading up to this event, I Had stopped Kea perhaps 3 times as follows:

config add Init/components b10-dhcp4
config set Init/components/b10-dhcp4/kind dispensable
config commit

And restarted as follows:

config remove Init/components b10-dhcp4
config commit
Dhcp4 shutdown

At this point, the Kea service does not seem recoverable, even when I stop/start again in bindctl as above. I had to initiate a complete BIND10 shutdown and then kick off BIND10 again in order for me to re-establish DHCP service:

Init shutdown

$ sudo /home/test/var/test-anvl/sbin/bind10 &> /home/test/var/test-anvl/bind10.log

Here are the relevant entries from the BIND10 logfile (/home/test/var/test-anvl/bind10.log):

2013-07-08 17:05:52.456 ERROR [b10-init.init/7940] BIND10_CONFIGURATOR_PLAN_INTERRUPTED configurator plan interrupted, only 0 of 1 done
2013-07-08 17:05:52.458 ERROR [b10-cmdctl.cmdctl/7946] CMDCTL_COMMAND_ERROR error in command set_config to module ConfigManager?: [Errno 32] Broken pipe

Subtickets

Change History (4)

comment:1 Changed 7 years ago by jreed

This may be related to #2757.

comment:2 Changed 7 years ago by shane

  • Milestone changed from New Tasks to DHCP Outstanding Tasks

comment:3 Changed 6 years ago by tomek

Also see #3074.

comment:4 Changed 6 years ago by muks

  • Milestone changed from DHCP Outstanding Tasks to Sprint-20131015
  • Resolution set to fixed
  • Status changed from new to closed

This should be fixed as part of #3074.